Check coolant levels
check oil level as it does use a little bit, in this video has it over full as Jake had just serviced it.

Check diesel levels
Have the top valve in this position (closed) to start it if the pumping shut off the pump, has no prime open the blue tap and pump the silver leaver till water is coming out then close the blue tap to keep prime.
loosen the fiction ring on the throttle flick the key on and hold in the Murphy switch and start the gen set, keep the Murphy switch held in for 3 seconds.Once gen set is running turn the top valve to open. Leave the pump idling until water is coming out the end gun

Leave pump idling until water comes out the end gun

Once water has started coming out then turn the speed dial anticlockwise. Till the gage is just below 2000 rpm
Time clock is set for 30 as the current run is 37 hours

Check the pressure gage on the hh ideally you want it between 100-120

Throttle up (anticlockwise) or down (clockwise) accordingly and tighten friction ring.