Knowby
Check for and rectify potential central locking connection fault
1
Step 1 of 6

While canopy door is fully open remove all of the 6mm bolts holding light panel on the door stiffener. Ensuring the panel does not drop when removing final bolt.

2
Step 2 of 6

Disconnect the white terminal as shown to fully remove the panel with the light attached. Once again being careful the panel does not drop when this takes place

3
Step 3 of 6

Place the removed light panel in a secure location

4
Step 4 of 6

Depending on what lock has the issue, identify the blue terminal closest to the affected lock and disconnect.

5
Step 5 of 6

The blades in the terminal on the 'male' side should be central to the terminal and not offset. If one is offset make sure it is manipulated back to centre.

6
Step 6 of 6

Re connect the blue terminal and try the central locking to check for success. If this is successful the harness and light panel can be reinstated by reversing steps 1-4.