Knowby
Wacker Neuson RC50 and RC70 Rollers – Start-Up and Vibration
How to start up Wacker Neuson pro rollers in the 5 to 7 ton class (RC50, RC50P, RC70, RC70P) and turn the vibration functions on and off.
How to start up Wacker Neuson pro rollers in the 5 to 7 ton class (RC50, RC50P, RC70, RC70P) and turn the vibration functions on and off.
1
Step 1 of 12

Enter the cab

Enter the cab, always maintaining three points of contact, and fasten your safety belt.

2
Step 2 of 12

Set the drive lever to park

Make sure the drive lever is set to park.

3
Step 3 of 12

Key the roller on

Key the roller on and start up.

4
Step 4 of 12

Press the vibration button

Press the vibration button on the control panel.

Depending on the roller model, you can use this button to switch between large and small amplitude vibration.

5
Step 5 of 12

Know your model's vibration

  • RC50, RC50P and RC70P: large amplitude only.

  • RC70: switches between large and small amplitude.

Rollers in the 5 to 7 ton class only offer manual vibration modes.

6
Step 6 of 12

Set the working gear

Set your working gear to first (turtle).

If you switch between working gear modes, the drive lever has to come back to the park position to confirm the change.

7
Step 7 of 12

Set the engine speed

Set your engine speed to MAX or ECO.

8
Step 8 of 12

Sound the horn

Sound the horn to let people know you are about to start working.

9
Step 9 of 12

Move the drive lever to neutral

Move the drive lever to neutral.

10
Step 10 of 12

Start vibration

Press the vibration button on the drive lever to start vibration.

11
Step 11 of 12

Begin travel

Move the lever forward or reverse to begin travel.

12
Step 12 of 12

Finish work

When you have finished working, press the vibration button on the lever to turn the vibration off, and put the machine in park.