Take the ad blue hose a cut hose following the instructions on the template.
Swap ends of where the two parts of the hose connects like so.
Copy the angle at which the two parts of the hose sits.
Attach the filler hose to the tank.
Attach the other end of the hose to the ad blue filler.
Cable tie the hose at the shown points.
Fasten all hose clamps .
Take the ad blue return/brether hose and cut following the instructions on the template.
Continue cutting the hose following the instructions as per the template.
Where “1” is marked on the template, attach these two ends together.
Connect the hose to the tank.
Connect the other end of the hose to the breather box
Connect the hose to the ad blue filler and the other end to the breather box
Secure all hoses with hose clamps.
Cable tie the hoses at the shown points.
Your ad blue hose set up should be looking like so.