Knowby
Gopfert Pre-feeder Isolation
Isolating pre-feeder entry table for maintenance and cleaning
Isolating pre-feeder entry table for maintenance and cleaning
1
Step 1 of 6
<p><strong>Empty Prefeeder Conveyor:</strong></p><p></p><p>Use control panel to reverse board from pre-feeder conveyor onto the Ascor belts.</p>

Empty Prefeeder Conveyor:

Use control panel to reverse board from pre-feeder conveyor onto the Ascor belts.

2
Step 2 of 6

Align Red Arrows:

Use the Up-down switch on control panel to align red arrows as shown

3
Step 3 of 6

Switch Off Feeder Table Motors:

  • Turn interlock key to off position.

  • Remove the key and place it on your wrist

4
Step 4 of 6

Engage Table Locking Pins:

Turn and push the table safety locking pins into place as shown.

5
Step 5 of 6

Raise the Safety Stands:

Raise the table safety stands ensuring they are aligned with table frame as shown.

6
Step 6 of 6

LOTO Locking Pins and Safety Stands:

Use chains to LOTO stands to ensure stands cannot fall and locking pins cannot be disengaged during work.