Knowby
Line Control - Dry Side BOTTLES
Line Control will run the conveyors and product speed when running line 6 and 10 dry side
Line Control will run the conveyors and product speed when running line 6 and 10 dry side
1
Step 1 of 9
<p>There are 5 Main line control panels</p><p></p><p></p><ol><li><p>The main Control panel pre line 6 filler</p></li><li><p>Singuliser controller before main control panel</p></li><li><p>Singuliser Controller before blower</p></li></ol><p>4. Remote Singuliser box before evotech</p><p>5.Remote Singuliser box after the carton coder</p><p></p><p></p><p></p>

There are 5 Main line control panels

  1. The main Control panel pre line 6 filler

  2. Singuliser controller before main control panel

  3. Singuliser Controller before blower

4. Remote Singuliser box before evotech

5.Remote Singuliser box after the carton coder

2
Step 2 of 9
<p>Go to the Main Control panel located pre- filler (Controller 1)</p><p>1.Press <em>'Bottle'</em> on top line</p><p>2.Move arrow <em>'up or down' </em>to correct format</p><p>3.Press '<em>Green tick'</em></p><blockquote><p>Format will be displayed at the bottom</p></blockquote><p>4.Press <em>'Pac'</em> &amp; <em>'Bot'</em> to start conveyors</p><blockquote><p>When changing formats the conveyors must be stopped</p></blockquote><p>5.Reset alarms by pressing the '<em>eye</em>' and press <em>'reset'</em> button</p>

Go to the Main Control panel located pre- filler (Controller 1)

1.Press 'Bottle' on top line

2.Move arrow 'up or down' to correct format

3.Press 'Green tick'

Format will be displayed at the bottom

4.Press 'Pac' & 'Bot' to start conveyors

When changing formats the conveyors must be stopped

5.Reset alarms by pressing the 'eye' and press 'reset' button

3
Step 3 of 9
<p>At the singuliser before the main panel there will be bottles from the depal to filler (Controller 2)</p><p></p><p>1.Press yellow <em>'compacting'</em> button</p><p></p><blockquote style="background-color: var(--k-quote-bg-error);"><p>When bringing in bottles to the filler make sure that we watch for fallen bottles otherwise this may cause a bottle crash</p></blockquote><p></p>

At the singuliser before the main panel there will be bottles from the depal to filler (Controller 2)

1.Press yellow 'compacting' button

When bringing in bottles to the filler make sure that we watch for fallen bottles otherwise this may cause a bottle crash

4
Step 4 of 9
<p>At the singuliser before the blower which controls from the filler to the labeller (Controller 3)</p><p></p><p>1.Press <em>'compacting'</em> button</p><p></p><blockquote style="background-color: var(--k-quote-bg-error);"><p>When bringing in bottles to the labeller make sure that we watch for fallen bottles otherwise this may cause a bottle crash</p></blockquote><p></p>

At the singuliser before the blower which controls from the filler to the labeller (Controller 3)

1.Press 'compacting' button

When bringing in bottles to the labeller make sure that we watch for fallen bottles otherwise this may cause a bottle crash

5
Step 5 of 9
<p>At the remote singuliser box before the Evo tech there which control's bottles into the packers (Controller 4)</p><p></p><p>1.Press Green <em>'Start' </em>Button</p><p></p><blockquote style="background-color: var(--k-quote-bg-error);"><p>When bringing in bottles to the packers make sure that we watch for fallen bottles otherwise this may cause a bottle crash</p></blockquote><p></p>

At the remote singuliser box before the Evo tech there which control's bottles into the packers (Controller 4)

1.Press Green 'Start' Button

When bringing in bottles to the packers make sure that we watch for fallen bottles otherwise this may cause a bottle crash

6
Step 6 of 9
<p>At the remote singuliser box which is controlling to the palletiser (Controller 5)</p><p></p><ol><li><p>Press Green <em>'Start'</em> Button</p></li></ol><blockquote style="background-color: var(--k-quote-bg-error);"><p>Be wary of turned cartons</p></blockquote><p></p>

At the remote singuliser box which is controlling to the palletiser (Controller 5)

  1. Press Green 'Start' Button

Be wary of turned cartons

7
Step 7 of 9
<p>There are also other remote singuliser boxes located around the area</p><p></p><ol><li><p>Next to the lab equipment</p></li></ol><p>2.Prior to the labeller</p><p>3.Prior to the filler</p><p></p><p>These can be used to used stop, start or empty machine</p><p></p>

There are also other remote singuliser boxes located around the area

  1. Next to the lab equipment

2.Prior to the labeller

3.Prior to the filler

These can be used to used stop, start or empty machine

8
Step 8 of 9
<p>When emptying out the line</p><p></p><p>Depal will have finished</p><p>1.Go filler singuliser controller to the right of the main panel Press <em>'emptying' </em>button (Controller 2)</p><p></p><p>Bottle will have stopped adjacent to the lab equipment</p><ol start="2"><li><p>Go to labeller singuliser controller before blower Press <em>'Emptying'</em> button (Controller 3)</p></li></ol><p></p><p>Bottles will have stopped prior going into the evo tech</p><p>3.Go to Remote singuliser box before evotech and press <em>'empty' </em>button</p><p>(Controller 4)</p><p></p><p></p><p></p><p></p><p></p><p></p>

When emptying out the line

Depal will have finished

1.Go filler singuliser controller to the right of the main panel Press 'emptying' button (Controller 2)

Bottle will have stopped adjacent to the lab equipment

  1. Go to labeller singuliser controller before blower Press 'Emptying' button (Controller 3)

Bottles will have stopped prior going into the evo tech

3.Go to Remote singuliser box before evotech and press 'empty' button

(Controller 4)

9
Step 9 of 9
<p>When the line is Finished turn off line on control on main panel (controller 1)</p><p></p><p>1.Press Red <em>'Pac'</em> &amp; <em>'Bot'</em></p>

When the line is Finished turn off line on control on main panel (controller 1)

1.Press Red 'Pac' & 'Bot'