Knowby
Wacker Neuson TH627 Telehandler – Overload Calibration
Overload calibration procedure for the Wacker Neuson TH627 telehandler, following the on-screen instructions of Wacker Neuson's service film: System Check button on the OMD, counterweight, 0% and 40% settings. The film has no narration.
Overload calibration procedure for the Wacker Neuson TH627 telehandler, following the on-screen instructions of Wacker Neuson's service film: System Check button on the OMD, counterweight, 0% and 40% settings. The film has no narration.
1
Step 1 of 19

Start in calibration mode

Press and hold the System Check button on the OMD and start the machine.

2
Step 2 of 19

Release the System Check button

With the engine running, release the System Check button.

3
Step 3 of 19

Press when the green lights meet

When the scrolling green lights meet, press the System Check button.

4
Step 4 of 19

Park the machine

Park on a flat, level surface and apply the parking brake.

5
Step 5 of 19

Place the counterweight and forks

Place the counterweight and forks in front of the machine.

Counterweight: 2,866–3,968 lb (1,300–1,800 kg).

6
Step 6 of 19

Retract the telescopic arm

Retract the telescopic arm to the minimum position.

7
Step 7 of 19

Raise the boom fully

Boom up to the maximum position to calibrate the 0% setting.

8
Step 8 of 19

Wait and press System Check

With the boom fully extended, wait 10 seconds and press the System Check button.

9
Step 9 of 19

Watch the lights

Three green lights will illuminate, followed by a single red light.

10
Step 10 of 19

Lower the boom

Lower the boom after the red light illuminates on the OMD.

11
Step 11 of 19

Attach the forks and counterweight

Extend the telescopic arm and attach the forks and counterweight.

12
Step 12 of 19

Raise the load 12 inches

Raise the boom and counterweight approximately 12 in (30 cm) off the ground.

13
Step 13 of 19

Extend until the rear wheels lift

Extend the telescopic arm until the rear wheels lift off the ground.

14
Step 14 of 19

Measure the telescopic arm

Measure the telescopic arm dimension from the extension arm pin bolt to the front of the telescopic arm.

15
Step 15 of 19

Calculate the 40% setting

Calculate the 40% extension arm setting.

Example shown: 70 in × 0.40 = 28 in.

16
Step 16 of 19

Mark the telescopic arm

Mark 28 in (71 cm) from the front of the telescopic arm.

17
Step 17 of 19

Retract to the mark

Retract the extension arm until the mark meets the front of the lift arm.

18
Step 18 of 19

Finish the calibration

  1. Press the System Check button.

  2. The light will flash.

  3. When the lights stop flashing, calibration is complete.

19
Step 19 of 19

Keep to the sequence

If the calibration procedure is performed out of sequence, the procedure will have to be re-calibrated from the beginning.