Wacker Neuson BS50-2i and BS60-2i Rammers – Starting
Starting procedure for the Wacker Neuson BS50-2i and BS60-2i two-stroke oil-injected rammers: throttle, choke, purge bulb, rope starter, opening the throttle and the low oil level shutdown.
Starting procedure for the Wacker Neuson BS50-2i and BS60-2i two-stroke oil-injected rammers: throttle, choke, purge bulb, rope starter, opening the throttle and the low oil level shutdown.
1
Step 1 of 5Set the throttle to idle
Set the throttle to the idle position.
This automatically turns on the flow of fuel.
2
Step 2 of 5Close the choke and pump the purge bulb
Close the choke.
Pump the purge bulb six to ten times, or until you see fuel in the bulb.
The engine will not become flooded by pumping the purge bulb more than ten times.
Pumping the purge bulb removes air from the fuel system. It does not pump fuel into the carburettor.
3
Step 3 of 5Pull the rope starter
Pull the rope starter and repeat until the engine starts, typically in less than ten seconds.
4
Step 4 of 5Open the throttle
After idling for a second, open the throttle to the full position.
When you do this, the choke opens automatically.
5
Step 5 of 5Low oil level shutdown
The engine is equipped with a low oil level shutdown switch.
If the engine stops running after 15 to 30 seconds, check the oil level.