Knowby
Wacker Neuson BS50-2i and BS60-2i Rammers – Starting
Starting procedure for the Wacker Neuson BS50-2i and BS60-2i two-stroke oil-injected rammers: throttle, choke, purge bulb, rope starter, opening the throttle and the low oil level shutdown.
Starting procedure for the Wacker Neuson BS50-2i and BS60-2i two-stroke oil-injected rammers: throttle, choke, purge bulb, rope starter, opening the throttle and the low oil level shutdown.
1
Step 1 of 5

Set the throttle to idle

Set the throttle to the idle position.

This automatically turns on the flow of fuel.

2
Step 2 of 5

Close the choke and pump the purge bulb

  1. Close the choke.

  2. Pump the purge bulb six to ten times, or until you see fuel in the bulb.

  • The engine will not become flooded by pumping the purge bulb more than ten times.

  • Pumping the purge bulb removes air from the fuel system. It does not pump fuel into the carburettor.

3
Step 3 of 5

Pull the rope starter

Pull the rope starter and repeat until the engine starts, typically in less than ten seconds.

4
Step 4 of 5

Open the throttle

After idling for a second, open the throttle to the full position.

When you do this, the choke opens automatically.

5
Step 5 of 5

Low oil level shutdown

The engine is equipped with a low oil level shutdown switch.

If the engine stops running after 15 to 30 seconds, check the oil level.