Laser 12 – Nozzle change and height calibration
HSG Laser > Maintenance. When and how to change the nozzle, and calibrating the height sensor afterwards.
HSG Laser > Maintenance. When and how to change the nozzle, and calibrating the height sensor afterwards.
1
Step 1 of 8
<p>Change the nozzle when the cut file calls for a different one, or when it shows crash damage or scratches. A good nozzle has a clean, round hole (right). A damaged one has a ragged hole (left).</p>

Change the nozzle when the cut file calls for a different one, or when it shows crash damage or scratches. A good nozzle has a clean, round hole (right). A damaged one has a ragged hole (left).

2
Step 2 of 8
<p>Check which nozzle you need at the top of the parameter chart.</p>

Check which nozzle you need at the top of the parameter chart.

3
Step 3 of 8
<p>Bring the head to the operator end and shut off the positive pressure blow-off.</p>

Bring the head to the operator end and shut off the positive pressure blow-off.

4
Step 4 of 8
<p>Unscrew the old nozzle by hand. Use the nozzle tool only if it&#39;s too tight.</p>

Unscrew the old nozzle by hand. Use the nozzle tool only if it's too tight.

5
Step 5 of 8
<p>Fit the new nozzle hand tight only.</p>

Fit the new nozzle hand tight only.

6
Step 6 of 8
<p>Lower the head manually until it is about 5 mm from the sheet, then click Calibrate.</p>

Lower the head manually until it is about 5 mm from the sheet, then click Calibrate.

7
Step 7 of 8

Recalibrate every time you change sheet thickness.

8
Step 8 of 8

If cutting is poor afterwards, check nozzle centring (Laser 13).