Laser 12 – Nozzle change and height calibration
HSG Laser > Maintenance. When and how to change the nozzle, and calibrating the height sensor afterwards.
HSG Laser > Maintenance. When and how to change the nozzle, and calibrating the height sensor afterwards.
1
Step 1 of 8
Change the nozzle when the cut file calls for a different one, or when it shows crash damage or scratches. A good nozzle has a clean, round hole (right). A damaged one has a ragged hole (left).
2
Step 2 of 8
Check which nozzle you need at the top of the parameter chart.
3
Step 3 of 8
Bring the head to the operator end and shut off the positive pressure blow-off.
4
Step 4 of 8
Unscrew the old nozzle by hand. Use the nozzle tool only if it's too tight.
5
Step 5 of 8
Fit the new nozzle hand tight only.
6
Step 6 of 8
Lower the head manually until it is about 5 mm from the sheet, then click Calibrate.
7
Step 7 of 8Recalibrate every time you change sheet thickness.
8
Step 8 of 8If cutting is poor afterwards, check nozzle centring (Laser 13).