

Laser 15 – Lower protective window change
Category: HSG Laser > Maintenance. When and how to check and change the lower protective window in the cutting head, without letting dust in.
Category: HSG Laser > Maintenance. When and how to check and change the lower protective window in the cutting head, without letting dust in.
1
Step 1 of 5
Check the lower window when cut quality goes bad. Shine a phone torch up from underneath to look for dirt or burn marks.
2
Step 2 of 5
Wipe down the entire head before you pull any window out.
3
Step 3 of 5
Pull the window drawer and change the window on a clean surface.
4
Step 4 of 5
Put tape over the opening while the drawer is out, so no dust gets into the head.
5
Step 5 of 5
The window sits between two seals. Make sure there is a seal above and below it before you refit the drawer. Spare windows: HSG protective lens D37 x 7 mm, 4–6 kW, item code 050806BC002.