Laser 13 – Beam alignment and nozzle centring (tape shot)
Category: HSG Laser > Calibration. Check the beam comes out the centre of the nozzle with a tape shot, and adjust it with the two screws in the head.
Category: HSG Laser > Calibration. Check the beam comes out the centre of the nozzle with a tape shot, and adjust it with the two screws in the head.
1
Step 1 of 7
<p>Fit a new 1.2 mm nozzle before you start, so a worn nozzle doesn&#39;t give a false result.</p>

Fit a new 1.2 mm nozzle before you start, so a worn nozzle doesn't give a false result.

2
Step 2 of 7
<p>Stick tape across the bottom of the nozzle.</p>

Stick tape across the bottom of the nozzle.

3
Step 3 of 7
<p>Fire a pierce through the tape.</p>

Fire a pierce through the tape.

4
Step 4 of 7
<p>Take the tape off and check the laser pierce is centred in the nozzle hole. If it is centred, you&#39;re done.</p>

Take the tape off and check the laser pierce is centred in the nozzle hole. If it is centred, you're done.

5
Step 5 of 7
<p>If the pierce is off centre, open the head cover. Loosen the two big screws by hand.</p>

If the pierce is off centre, open the head cover. Loosen the two big screws by hand.

6
Step 6 of 7
<p>Adjust the beam with the allen key, using the left and right adjustment screws shown in the diagram. Each screw moves the beam in the direction of its arrow.</p>

Adjust the beam with the allen key, using the left and right adjustment screws shown in the diagram. Each screw moves the beam in the direction of its arrow.

7
Step 7 of 7

Retighten the two big screws, then do another tape shot with fresh tape. Repeat until the pierce is centred, then close the head cover.