1
Step 1 of 10

Follow the 10 second rule: wait 10 seconds between each step below.

2
Step 2 of 10

Turn on the main power.

3
Step 3 of 10

Turn on the chiller.

4
Step 4 of 10

Turn on the air compressor: switch on at the wall outlet, check the dryer is running, then press start on the compressor panel.

5
Step 5 of 10
<p>Turn on the gas at the gas skid. Check the gas pressure reads 550 kPa before you cut.</p>

Turn on the gas at the gas skid. Check the gas pressure reads 550 kPa before you cut.

6
Step 6 of 10

Turn on the computer on the laser.

7
Step 7 of 10

Open CypCut.

8
Step 8 of 10

Turn the laser on.

9
Step 9 of 10

Turn the laser power on and wait 10 seconds. Then start the extractor: press the green Blower On button. (Red Blower Off stops it.)

10
Step 10 of 10

Turn the shutter on. The laser is ready to load a job (Laser 02).