Laser 18 – Changing gas bottles / packs
Laser category. Swapping an empty oxygen or nitrogen bottle or pack at the gas skid. Follow the gas-handling SOP for hazards and PPE. [REVIEW: general practice, no operator notes yet]
Laser category. Swapping an empty oxygen or nitrogen bottle or pack at the gas skid. Follow the gas-handling SOP for hazards and PPE. [REVIEW: general practice, no operator notes yet]
1
Step 1 of 7
Pause or finish the job. Never change gas mid-cut.
2
Step 2 of 7
Close the cylinder or pack valve on the empty bottle, then vent the line at the regulator.
3
Step 3 of 7
Undo the connection, cap the empty bottle and tag it EMPTY. Chain it in the empties area.
4
Step 4 of 7Bring the full bottle on the trolley and chain it in place before you connect it.
5
Step 5 of 7
Check the fitting and seal are clean, connect, and tighten with the correct spanner. Never use oil or grease on oxygen fittings.
6
Step 6 of 7
Open the valve slowly. Check for leaks with leak spray, then check the regulator reads 550 kPa (Laser 01).
7
Step 7 of 7Order a replacement if you used the last full bottle.