Knowby
Laser 18 – Changing gas bottles / packs
Laser category. Swapping an empty oxygen or nitrogen bottle or pack at the gas skid. Follow the gas-handling SOP for hazards and PPE. [REVIEW: general practice, no operator notes yet]
Laser category. Swapping an empty oxygen or nitrogen bottle or pack at the gas skid. Follow the gas-handling SOP for hazards and PPE. [REVIEW: general practice, no operator notes yet]
1
Step 1 of 7
<p>Pause or finish the job. Never change gas mid-cut.</p>

Pause or finish the job. Never change gas mid-cut.

2
Step 2 of 7
<p>Close the cylinder or pack valve on the empty bottle, then vent the line at the regulator.</p>

Close the cylinder or pack valve on the empty bottle, then vent the line at the regulator.

3
Step 3 of 7
<p>Undo the connection, cap the empty bottle and tag it EMPTY. Chain it in the empties area.</p>

Undo the connection, cap the empty bottle and tag it EMPTY. Chain it in the empties area.

4
Step 4 of 7

Bring the full bottle on the trolley and chain it in place before you connect it.

5
Step 5 of 7
<p>Check the fitting and seal are clean, connect, and tighten with the correct spanner. Never use oil or grease on oxygen fittings.</p>

Check the fitting and seal are clean, connect, and tighten with the correct spanner. Never use oil or grease on oxygen fittings.

6
Step 6 of 7
<p>Open the valve slowly. Check for leaks with leak spray, then check the regulator reads 550 kPa (Laser 01).</p>

Open the valve slowly. Check for leaks with leak spray, then check the regulator reads 550 kPa (Laser 01).

7
Step 7 of 7

Order a replacement if you used the last full bottle.